Summary0000496: SANE 1.0.22: "unrecognized option `--lamp-off'"
DescriptionOn 08Dec, 2004, Henning Meier-Geinitz took on a feature request of mine, to allow my scanner to have its lamp turned off and scan head parked when requested.

He added the feature in the mustek backend, v1.38:

2005-05-05:
  * Released Mustek backend 1.0-138
  * Added options to set the time after which the lamp of the A3 Pro is shut
    off and to shut it off immediately.

I somehow acquired these files, which incorporated the feature:

scanimage .exe 53,295 .a.. 5-09-05
libsane .dll 109,724 .a.. 5-09-05

[d:\SANE]scanimage -V
scanimage (sane-backends) 1.0.15; backend version 1.0.15

scanimage --lamp-off --dont-scan
[result: scanner turns off lamp and parks]

=================================
However, this does not work for the newer scanimage.exe:

[D:\tame]scanimage -V
scanimage (sane-backends) 1.0.22; backend version 1.0.22

D:\tame]scanimage --lamp-off --dont-scan
scanimage: unrecognized option `--lamp-off'
TagsNo tags attached.

Activities

psmedley

2011-12-17 23:26

administrator   ~0002067

Looking at the code, the feature seems to only be enabled for one specific model of scanner:
1200 A3 PRO

What is your scanner detected as?

asavage

2011-12-18 23:03

reporter   ~0002068

"1200 A3 PRO" is the model of my scanner

First, the old (working) version:

[D:\tame\old]scanimage -V
scanimage (sane-backends) 1.0.15; backend version 1.0.15

[D:\tame\old]scanimage -L
device `mustek:b0t6l0' is a Mustek 1200 A3 PRO flatbed scanner
device `test:0' is a Noname frontend-tester virtual device
device `test:1' is a Noname frontend-tester virtual device


The current version:

[D:\tame]scanimage -V
scanimage (sane-backends) 1.0.22; backend version 1.0.22


[D:\tame]scanimage -L
device `pixma:MX860_192.168.0.104' is a CANON Canon PIXMA MX860 multi-function p
eripheral
device `mustek:b0t6l0' is a Mustek 1200 A3 PRO flatbed scanner
device `test:0' is a Noname frontend-tester virtual device
device `test:1' is a Noname frontend-tester virtual device

asavage

2013-02-10 20:04

reporter   ~0002406

Last edited: 2013-02-10 23:49

I found the problem.

Back in the day, we had only one scanner that scanimage could find: the Mustek. Unless specified, scanimage sends commands to the backend of the first scanner it finds.

I moved in with someone who has another scanner on the network: the Canon Pixma MX860 listed above.

The Pixma comes up first in the list of scanners found. scanimage sends the "--lamp-off --dont-scan" command to the first scanner it found, and the Pixma backend replies, "I don't know what you're talking about".

Solution: specify which scanner on the commandline:

[D:\sane]scanimage -d mustek --lamp-off --dont-scan
[turns off lamp & parks]

It was operator error all along.

This can be closed. Thanks.

Issue History

Date Modified Username Field Change
2011-11-19 23:02 asavage New Issue
2011-12-17 23:26 psmedley Note Added: 0002067
2011-12-18 23:03 asavage Note Added: 0002068
2013-02-10 20:04 asavage Note Added: 0002406
2013-02-10 23:49 asavage Note Edited: 0002406
2013-02-17 08:44 psmedley Status new => resolved
2013-02-17 08:44 psmedley Resolution open => no change required
2013-02-17 08:44 psmedley Assigned To => psmedley
2020-08-24 03:13 psmedley Status resolved => closed